Installation, Operation and Maintenance Manual
5
1. Determine System Location (see Figures 1 and 2)
The Drinking Water Filtration System can be located under a sink or in a basement depending on space avail-
ability and preference. If a basement installation is selected, additional tubing, hardware and fi ttings may be
needed and a hole will have to be made from inside the cabinet, through the fl oor, to the basement.
Space Requirements
NOTE: Never install the fi ltration system in an area of the home
where the temperature may drop below 40° as damage to the
system will result.
The exact placement of the various components of the fi ltration
system will vary from installation to installation. The installer must
decide on where to place the faucet, storage tank and Reverse
Osmosis (RO) assembly by balancing convenience with ease of
installation and servicing.
Considerations for an icemaker or other remote hookup should be predetermined, including plumbing
routing and any additional tools, fi ttings and tubing that may be required.
Feedwater Conditions Parameter Feedwater Conditions Parameter
pH 4-11 Manganese < 0.05 ppm (mg/L)
Hardness < 350 ppm (mg/L) Hydrogen Sulfi de None allowable
Iron (FE) < 0.1 ppm (mg/L) Organics < 1 ppm (mg/L)
Free Chlorine Up to 3 ppm (mg/L) Turbidity < 1 NTU
TDS Up to 2,000 ppm
Temperature 40-100°F (4-38°C)
Min./Max. Feedwater pressure 30-125 psi (207 -862 kPa)
2. Prepare the Area for Installation
Determine where components will be located and how they will be mounted. Special mounting brackets
and hardware may be necessary to secure the system to a wall or ceiling joists if a basement installation is
called for. Inspect the cold water supply line and drain to determine if any additional fi ttings are required.
NOTE: It is a good idea at this time to check the condition of the under counter plumbing for any existing
or potential leaks.
3. Prepare the Drinking Water Filtration System for Installation
Open the shipping carton and remove components. Check that all of the installation parts are present which
include the reverse osmosis (RO) assembly, storage tank, faucet, installation hardware, and tubing located
in box under storage tank. (See Parts List on page 15)
If an optional percent rejection monitor is used, the probes should be installed at this time. Follow the in-
structions that come with the monitor.
14 5/8" NOM
6 1/2"
14 1/8" NOM
2"
Minimum Distance
Required To Remove
Cartridges
To reduce the risk associated with property damage due to
water leakage:
Protect from freezing. Drain fi lter when temperatures drop below
40°F (4.4°C).
Do not install if water pressure exceeds 125 psi (862 kPa). If
your water pressure exceeds 80 psi, you must install a pressure
limiting valve. Contact a plumbing professional if you are uncer-
tain how to check your water pressure.
CAUTION