INSTALLATION AND OPERATING
INSTRUCTIONS
APUN SERIES
UPFLOW ACID NEUTRALIZERS
MODELS:
APUN101
APUN201
APUN301
APUN100-LM
APUN200-LM
INSTR2195 0412
Installer, please leave with homeowner.
Homeowner, retain for future reference.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONSAPUN SERIESUPFLOW ACID NEUTRALIZERS MODELS: APUN101 APUN201 APUN301 APUN100-LM APUN200-LMINSTR2195

Page 2

6SECTION 6: COMPONENT PARTSRef NumberDescription APUN100-LM APUN101 APUN200-LM APUN201 APUN3011 Upfl ow Head (Includes Fill-port) 6238131 6238131 62381

Page 3

7SECTION 6: PARTSCOMPONENT PARTS LISTBypass Valve (Part Number V3006)Drawing No. Order No. Description Quantity1 V3151 Nut 1” Quick Connect 22 V3150 S

Page 4 - IMPORTANT NOTES

Aqua-Pure is a trademark of 3M Company used under license. 3M is a trademark of 3M Company.© 2012 3M Company. All rights reserved.3M Purifi cation Inc

Page 6 - SECTION 2: INSTALLATION

SAFETY INFORMATIONRead, understand, and follow all safety information contained in these instructions prior to installation and use of the APUN Series

Page 7 - IMPORTANT NOTE

CAUTIONTo reduce the risk associated with property damage due to water leakage:• Read and follow Use instructions before installation and use of this

Page 8 - SECTION 3: MAINTENANCE

SECTION 1: HOW A NEUTRALIZER WORKSThe low pH (acid) water passes through a special limestone neutralizing media and slowly dissolves the media raising

Page 9 - SECTION 5: SPECIFICATIONS

SECTION 2: INSTALLATIONCAUTIONTo reduce the risk associated with property damage due to water leakage:• Installation and use MUST comply with existin

Page 10 - SECTION 6: COMPONENT PARTS

Step 5After completion of plumbing connections, remove fi ll-port cap using wrench provided and pour neutralizer media into mineral tank using funnel p

Page 11 - SECTION 6: PARTS

4SECTION 3: MAINTENANCEThe media in this the APUN Series Upfl ow Acid Neutralizer System is sacrifi cial, therefore it must be replenished periodically.

Page 12 - Section 7: LIMITED WARRANTY

SECTION 4: TROUBLESHOOTINGProblem Possible SolutionsA. Neutralizer overcorrects upon installation or after replenishment. 1. The inlet bypass can b